Nonlinear study of injection process types into the traveling wave tube with hollow electron beam
محورهای موضوعی : Journal of Theoretical and Applied PhysicsH. Bayati 1 , S. Saviz 2 , A. H. Sari 3
1 - Plasma Physics Research Center, Science and Research Branch, Islamic Azad University
2 - Plasma Physics Research Center, Science and Research Branch, Islamic Azad University
3 - Plasma Physics Research Center, Science and Research Branch, Islamic Azad University
کلید واژه: Traveling wave tube (TWT), Hollow electron beam, Different signal injections, Harmonic and multiple injectio,
چکیده مقاله :
AbstractIn this paper, examples of all types of signal injection such as different signal , harmonic signal and multiple signal injections in a TWT including hollow electron beam near frequency 1800 MHz and within input powers lower than TWT saturation power has been analyzed using approximate analytical solution of S-MUSE model. Later, the results obtained from approximate analytical solution with large signal code LATTE, that is a Lagrangian model, have been tested and simulated so that the effect of input phase difference between drive and injected wave and the effect of input powers on the amplification value of drive and generated second-order harmonic waves were investigated. The phase difference between drive and harmonic waves is a key parameter in harmonic injection for increasing the output power of drive and second-order harmonic frequencies.