journal of Artificial Intelligence in Electrical Engineering
,
Issue4,Year,
Autumn
2020
In this work, we calculate optimum thickness of bulk active layer for Ga As/〖Al〗_x 〖Ga〗_(1-x) As laser diodes. We have done these calculations for fundamental oscillation mode of laser with different aluminium contents (fractional percents) in confinement layers. Our ca More
In this work, we calculate optimum thickness of bulk active layer for Ga As/〖Al〗_x 〖Ga〗_(1-x) As laser diodes. We have done these calculations for fundamental oscillation mode of laser with different aluminium contents (fractional percents) in confinement layers. Our calculations were based on the analytical solution of Maxwell equations. The results indicate that the optimum thickness for fundamental mode is dependent on difference of refractive indices of active and confinement layers. The results reveal that the best active layer thicknesses for fundamental mode of laser are d_0=0.63,0.44,0.36 and 0.32 μm for x=0.1,0.2,0.3 and 0.4 aluminium percents in separate confinement heterostructure (SCH) layers respectively.
Manuscript profile
journal of Artificial Intelligence in Electrical Engineering
,
Issue1,Year,
Winter
2023
In this paper we study the acquisition of fundamental TE mode reflection in rectangular cavities from a tilted face (end mirror) of superluminescent light emitting diodes (SLD). When its width is 3 micrometers and the inclination of the mirror is 3 ̊, the result will be More
In this paper we study the acquisition of fundamental TE mode reflection in rectangular cavities from a tilted face (end mirror) of superluminescent light emitting diodes (SLD). When its width is 3 micrometers and the inclination of the mirror is 3 ̊, the result will be a reduction of nearly 20 dB of reflection. While if the width is 6 micrometers, the inclination of the mirror 2 ̊ will cause an excess reflection loss of 20 dB. The results obtained in our paper for small tilt angles are the Gaussian approximation of the guided state. While our results differ greatly from the Gaussian approximation for larger angles and larger reflection losses.
Manuscript profile
The Application of Chemistry in Environment
,
Issue5,Year,
Winter
2021
این مقاله به تحلیل محتوای مجله کاربرد شیمی در محیط زیست بر اساس مفروضههای زیست محیطی با تأکید بر آموزش محیط زیست میپردازد. جامعه آماری مورد مطالعه تمام مقالات منتشر شده در شمارههای 35 الی 38 مجله است. دادههای پژوهش با به کارگیری ابزار سیاهه وارسی گردآوری و با استفاد More
این مقاله به تحلیل محتوای مجله کاربرد شیمی در محیط زیست بر اساس مفروضههای زیست محیطی با تأکید بر آموزش محیط زیست میپردازد. جامعه آماری مورد مطالعه تمام مقالات منتشر شده در شمارههای 35 الی 38 مجله است. دادههای پژوهش با به کارگیری ابزار سیاهه وارسی گردآوری و با استفاده از نرم افزار اکسل مورد تجزیه و تحلیل آماری قرار گرفتهاند. در این مقاله از روش تحلیل محتوای "آنتروپی شانون" برای پردازش دادهها به صورت کمی و کیفی کمک گرفته شده است. بر اساس شاخصهای آنتروپی محتوای مقالات بر اساس 7 مؤلفه اصلی و 93 مؤلفه فرعی آموزش محیط زیست مورد مطالعه قرار گرفته است. نتایج تحلیل نشان میدهد مؤلفههای اصلی مربوط به انسان و محیط زیست با 9 مقاله (1/32 درصد) و معضلات زیست محیطی آب با 7 مقاله (25 درصد) بیشترین فراوانی را به خود اختصاص دادهاند. مؤلفهی زباله و ارزش بازیافت با 1 مقاله فقط 6/3 درصد و مؤلفههای معضلات زیست محیطی هوا، خاک، صوت و حفاظت منابع طبیعی با 0 مقاله (صفر درصد) کمترین مقدار را به خود اختصاص دادهاند. یافتههای حاصل از فراوانی مؤلفهها نشان داده است که مؤلفههای آموزش محیط زیست از توزیع نرمال برخوردار نیستند و به بعضی از مؤلفهها پرداخته نشده است.
Manuscript profile
International Journal of Biophotonics and Biomedical Engineering
,
Issue1,Year,
Winter
2023
Optical coherence tomography (OCT) is a new imaging technique with a significant role in the field of medicine. It is a light-based non-invasive imaging method that provides high quality cross-sectional and volumetric images. OCT technology was introduced in the early 1 More
Optical coherence tomography (OCT) is a new imaging technique with a significant role in the field of medicine. It is a light-based non-invasive imaging method that provides high quality cross-sectional and volumetric images. OCT technology was introduced in the early 1990s and advanced to produce quicker obtaining times and higher resolution. In this article we discuss some of the recent advancements in OCT imaging systems. We will review a brief history and first operating principles including light coherence interferometry (LCI), time domain optical coherence tomography (TD-OCT) and Fourier domain optical coherence tomography (FD-OCT) contains two types: spectral domain optical coherence tomography (SD-OCT) and swept source optical coherence tomography (SS-OCT). Also we review recent emerging innovative OCT systems including Doppler OCT, polarization sensitive optical coherence tomography (PS-OCT), high resolution optical coherence tomography (HR-OCT), full field optical coherence tomography (FF-OCT), wide field optical coherence tomography (WF-OCT), optical coherence elastography (OCE), adaptive optics optical coherence tomography (AO-OCT), visible light optical coherence tomography (Vis-OCT), intraoperative optical coherence tomography (iOCT), hand-held optical coherence tomography (HH-OCT), and OCT in needle format.
Manuscript profile
The Application of Chemistry in Environment
,
Issue58,Year,
Summer
2024
حسگرها، عملکرد ارزشمندی را در مطالعات زیست محیطی، کشاورزی، بازرسی و ایمنی مواد غذایی، پاسخ سریع و مقرون به صرفه در بیوتکنولوژی، تشخیص بیماری و خدمات پزشکی و ... از خود نشان دادهاند. از میان بسیاری از دستههای حسگرها، حسگرهای زیستی نوری به دلیل اندازهگیریهای انتخابی، More
حسگرها، عملکرد ارزشمندی را در مطالعات زیست محیطی، کشاورزی، بازرسی و ایمنی مواد غذایی، پاسخ سریع و مقرون به صرفه در بیوتکنولوژی، تشخیص بیماری و خدمات پزشکی و ... از خود نشان دادهاند. از میان بسیاری از دستههای حسگرها، حسگرهای زیستی نوری به دلیل اندازهگیریهای انتخابی، سریع و بسیار حساس خود، دارای مزایای اضافی مانند استحکام، قابلیت اطمینان و پتانسیل ادغام بر روی تراشه هستند. در مورد حسگرهای زیستی نوری، آنالیت با استفاده از نور با تکنیکهای مبتنی بر برچسب یا بدون برچسب شناسایی میشود. در این مقاله برخی از پیشرفتهای قابل توجه در دهه گذشته در زمینه حسگرهای زیستی نوری با تاکید بر رویکردهای ساخت آنها و حوزههای کاربردی رو به رشد، بررسی شده است. همراه با برخی از مقالههای با دقت انتخاب شده در مورد پیشرفتهای جدید در حسگرهای زیستی نوری مروری کوتاه از حسگرهای زیستی نوری از زمان پیشرفت نیز ارائه شده است. همچنین چالشها و آینده فناوریهای حسگر زیستی نوری در حال ظهور در دهه جاری ارائه شده است.
Manuscript profile
Sanad
Sanad is a platform for managing Azad University publications