• فهرس المقالات reheater

      • حرية الوصول المقاله

        1 - Analysis and Simulation of Load Frequency Control in Power System with Reheater Steam Turbine
        Mehdi Riahinasab Neda Behzadfar Homa Movahednejad
        Power systems are a complex system, which to control them in steady state, different control loops are needed. Load changes affect the frequency of electrical networks. Frequency stabilization (FS) is very important due to the increasing penetration of renewable energy أکثر
        Power systems are a complex system, which to control them in steady state, different control loops are needed. Load changes affect the frequency of electrical networks. Frequency stabilization (FS) is very important due to the increasing penetration of renewable energy sources in power systems. The main task of load frequency control is to keep the system frequency according to the specified nominal value and to maintain the correct amount of exchange power between the control areas. In this paper, load frequency control (LFC) in single-area power system (SIPS) is studied and simulated. Each area has a steam generating unit with a reheat steam turbine. The system equations are expressed in the state space and the system model is determined based on the transfer function. The simulation results have been obtained using Matlab software. The simulation results show the effect of reheater's parameters on the transient dynamic behavior of the system. تفاصيل المقالة
      • حرية الوصول المقاله

        2 - Improved Dynamic Performance in Interconnected Power System Using Secondary Frequency Control
        Bahador Fani Farhad Mesrinejad Somaye Yaghoubi HassanHaes Alhelou
        Load changes affect the frequency of electrical networks. Frequency stabilization is very important due to the increasing penetration of renewable energy sources in power systems. Load frequency control (LFC) is used in the power system, so that the frequency of the pro أکثر
        Load changes affect the frequency of electrical networks. Frequency stabilization is very important due to the increasing penetration of renewable energy sources in power systems. Load frequency control (LFC) is used in the power system, so that the frequency of the programmed system and the power of the connection line of an interconnected area are within the specified limits. To improve the dynamic performance of the power system and control the frequency stability, LFC is used in power systems. The main task of LFC is to keep the system frequency according to the specified nominal value and to maintain the correct amount of exchange power between the control areas. In this paper, load frequency control in two-area power system is studied and simulated. Each area has a steam generating unit with a reheat steam turbine. The system equations are expressed in the state space and the system model is determined based on the transfer function. The simulation results have been obtained using Matlab software. The simulation results show the effect of Richter's parameters on the transient dynamic behavior of the system. تفاصيل المقالة
      • حرية الوصول المقاله

        3 - Secondary frequency control for improved dynamic performance in interconnected power system
        Farhad Mesrinejad Somaye Yaghoubi Bahador Fani
        Load changes affect the frequency of electrical networks. Frequency stabilization is very important due to the increasing penetration of renewable energy sources in power systems. The main task of load frequency control is to keep the system frequency according to the s أکثر
        Load changes affect the frequency of electrical networks. Frequency stabilization is very important due to the increasing penetration of renewable energy sources in power systems. The main task of load frequency control is to keep the system frequency according to the specified nominal value and to maintain the correct amount of exchange power between the control areas. Load frequency control in two-area power system is studied and simulated in this paper. Each area has a steam generating unit with a reheat steam turbine. The system equations are expressed in the state space and the system model is determined based on the transfer function. The simulation results have been obtained using Matlab software. The simulation results show the effect of reheater on the transient dynamic behavior of the two-area power system. تفاصيل المقالة