-
حرية الوصول المقاله
1 - Aging Study of Transformer Oil-Impregnated Repulped and Standard Cellulose by Measuring of 2-furfural Content of the Oil
Ali Ramazani Rana Rahmati Solmaz Bigdeli Sohrab Rahmani Mehrdad HamidiIn order to evaluate the reliability of using repulped cellulose in transformers, the aging process was applied on standard and repulped cellulose in a laboratory accelerated model by increasing of temperature to 150 ° C and their behavior was monitored by measuri أکثرIn order to evaluate the reliability of using repulped cellulose in transformers, the aging process was applied on standard and repulped cellulose in a laboratory accelerated model by increasing of temperature to 150 ° C and their behavior was monitored by measuring the amount of 2-furfural released in oil by HPLC (High Performance Liquid Chromatography) in the consecutive aging periods and the results was compared. The results were fitted to estimate the aging behaviors according to the content of 2 - furfural that released in oil. The obtained results showed that behavior of two types of cellulose is almost the same. Therefore, it can be concluded that the moulded insulating parts made of repulped cellulose can be used in the insulation system of power transformers with a good and acceptable reliability. تفاصيل المقالة -
حرية الوصول المقاله
2 - روش جدید تخمین امید هزینه خرابی ترانسفورماتورهای قدرت موازی
هادی شمس سولاری بهروز مجیدی مجید معظمیارزیابی سطح ریسک سیستم های قدرت و کاهش هزینههای در ارتباط با اثرات مخرب آن، به یکی از چالشهای اساسی بهرهبرداری و برنامهریزی صنعت برق تبدیل شده است. در این مقاله یک روش جدید به منظور مدل سازی ریاضی همبستگی خرابی ترانسفورماتورهای موازی با استفاده از فرآیند پواسون و ت أکثرارزیابی سطح ریسک سیستم های قدرت و کاهش هزینههای در ارتباط با اثرات مخرب آن، به یکی از چالشهای اساسی بهرهبرداری و برنامهریزی صنعت برق تبدیل شده است. در این مقاله یک روش جدید به منظور مدل سازی ریاضی همبستگی خرابی ترانسفورماتورهای موازی با استفاده از فرآیند پواسون و تابع مفصل گوسی چند متغیره ارائه شده است. در این روش با محاسبه شاخصهای انتخابی قابلیت اطمینان و هزینههای مرتبط با آن، یک روش مدل سازی به منظور تخمین امید ریاضی هزینه خرابی تراسفورماتورهای موازی با همبستگی خرابی و هزینه ریسک سالیانه سیستم قدرت پیشنهاد داده شده است. با توجه به توانایی تولید فرآیند گذر حالت واقعی سیستم برای شبیهسازی همبستگی و احتمال خرابی ترانسفورماتورهای موازی، از روش مونتکارلو ترتیبی برای محاسبه شاخصهای قابلیت اطمینان سیستم و همچنین تخمین هزینههای مذکور استفاده شده است. نتایج شبیهسازی روش پیشنهادی نشان میدهد که افزایش احتمال همبستگی خرابی ترانسفورماتورهای موازی در پستهای برق به صورت سالیانه، منجر به افزایش امید هزینه خرابی آنها، افزایش سطح و هزینه کل ریسک سیستم قدرت خواهد شد. تفاصيل المقالة -
حرية الوصول المقاله
3 - تشخیص خطای اتصال کوتاه در سیمپیچ ترانسفورماتور قدرت مبتنی بر سنجش ولتاژ و جریان سیمپیچ با استفاده از سیستم عصبی-فازی
همایون مشگین کلک مهیار محمدپورخرابی عایق بین حلقههای سیم پیچ یکی از دلایل اصلی خطای اولیه سیم پیچ در ترانسفورماتور است. در حین کار ترانسفورماتور، میدانهای الکتریکی قوی به مواد دی الکتریک سیم پیچهای آن اعمال میشود. خرابی و پیری دی الکتریک یکی از مهمترین عوامل خطای اتصال کوتاه در سیم پیچهای ترانس أکثرخرابی عایق بین حلقههای سیم پیچ یکی از دلایل اصلی خطای اولیه سیم پیچ در ترانسفورماتور است. در حین کار ترانسفورماتور، میدانهای الکتریکی قوی به مواد دی الکتریک سیم پیچهای آن اعمال میشود. خرابی و پیری دی الکتریک یکی از مهمترین عوامل خطای اتصال کوتاه در سیم پیچهای ترانسفورماتور است. به سبب فراوانی این خطا و احتمال گسترش آن، تشخیص و شناسایی آن در مراحل اولیه اهمیت دارد. در این مقاله نشان داده شده است که با سنجش و بررسی اختلاف فاز میان ولتاژ و جریان در فازهای ترانسفورماتور در حالت بارداری میتوان به وجود خطا پی برد. در این راستا اثر اتصال کوتاه حلقه در یک سیم پیچ بر سیم پیچهای دیگر نیز بررسی شده است. به منظور تشخیص خطای برخط، استفاده از یک سیستم هوشمند (سیستم عصبی-فازی)نیز پیشنهاد شده است. نتایج شبیه سازی و آزمایشگاهی برای یک ترانسفورماتور نمونه، بیانگر صحت و قابلیت روش ارائه شده در تشخیص برخط خطای سیم پیچ در ترانسفورماتور است. تفاصيل المقالة -
حرية الوصول المقاله
4 - عملکرد بهینه ترانسفورماتور قدرت الکترونیکی توزیع با استفاده از روش رگولاتور خطی درجه دو
محمد حسین رضایی رحمت اله هوشمند محمد عطاییترانسفورماتورها وظایفی همچون انتقال ولتاژ، ایزولاسیون و تفکیک نویز را بر عهده دارند و یکی از اجزاء ضروری سیستم توزیع قدرت الکتریکی هستند. در عین حال، در فرکانسهای صنعتی (50 هرتز) یکی از سنگینترین و گرانترین اجزا در سیستم توزیع هستند. امروزه از ترانسفورماتور قدرت الکت أکثرترانسفورماتورها وظایفی همچون انتقال ولتاژ، ایزولاسیون و تفکیک نویز را بر عهده دارند و یکی از اجزاء ضروری سیستم توزیع قدرت الکتریکی هستند. در عین حال، در فرکانسهای صنعتی (50 هرتز) یکی از سنگینترین و گرانترین اجزا در سیستم توزیع هستند. امروزه از ترانسفورماتور قدرت الکترونیکی به جای ترانسفورماتور قدرت معمولی استفاده میشود تا انتقال ولتاژ و تحویل توان در سیستم قدرت را انجام دهد. در این مقاله ساختار و روابط ترانسفورماتور قدرت الکترونیکی توزیع بررسی شده و سپس به طراحی یک رگولاتور خطی درجه دو با عمل انتگرالی برای بهبود عملکرد دینامیکی DEPT با حضور نامتعادلی ولتاژ، کمبود (sag) ولتاژ، هارمونیکهای ولتاژ و چشمک زنی ولتاژ پرداخته میشود. روش کنترل ارائه شده توسط MATLAB/SIMULINK شبیه سازی شده است. نتایج ارائه شده که شامل ولتاژ ورودی، ولتاژ خروجی و ولتاژ لینک DC در مقدار مرجع میباشند، بهبود عملکرد دینامیکی را تایید میکند. تفاصيل المقالة -
حرية الوصول المقاله
5 - Determination of a New Model to Study Ultra-Saturation Phenomenon During the Loaded Power Transformer Energization and its Effect on Differential
Bahram NoshadOne of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenome أکثرOne of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the power transformer is considered. In this model, the nonlinear characteristic of the power transformer core, the effect of current transformers, and the core losses of the power transformer are taken into account. It is assumed that the load of the power transformer is a resistive and inductive load. Also, the effect of the residual flux and inception angle on the ultra-saturation phenomenon are investigated. In this paper, simulation is done by MATLAB software. The differential protection of the power transformer must be accurate and fast, so the description of the ultra-saturation phenomena is the first level for preventing of the mal-operation of the differential protection. The outcomes of this research can further be used as hints for substation operation personnel as well as for the development of new protection stabilization criteria, which is not discussed further in this paper. تفاصيل المقالة -
حرية الوصول المقاله
6 - Power Auto-transformer Mechanical Faults Diagnosis Using Finite Element based FRA
Mojtaba Mahvi Vahid BehjatFrequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. أکثرFrequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in this paper a high ‎definition 3D FEM model of a three-phase, three-winding, 125-‎MVA power auto-transformer was constructed using finite ‎element method and verified by experimental FRA ‎measurements. Various radial deformations and axial ‎displacements were formed using FEM model and the extracted ‎parameters of the winding detailed model were used to obtain ‎power transformer frequency responses. The commonly used ‎appropriate statistical indices in FRA diagnosis were utilized for ‎interpreting FRA results. The study showed that the frequency ‎range between 1-100 kHz is mainly affected by the mechanical ‎faults and the 1st resonance of the double-peak feature of the ‎auto-transformer FRA remains unchanged during winding ‎radial deformation and axial displacement.‎ تفاصيل المقالة -
حرية الوصول المقاله
7 - Artificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers
A. R Moradi Y Alinejad Beromi K Kiani Z MoravejProtection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, أکثرProtection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network (ANN) which is trained by two different swarm based algorithms; Gravitational Search Algorithm (GSA) and Particle Swarm Optimization (PSO) have been used to discriminate between Current transformer saturation and fault currents in power transformers. In fact, GSA operates based on gravity law and in opposite of other swarm based algorithms, particles have identity and PSO is based on behaviors of bird flocking. Proposed approach has two general stages. In first step, obtained data from simulation have been processed and applied to an ANN, and then in second step, using training data considered ANN has been trained by GSA & PSO. Finally, a proposed technique has been compared with one of the common training approach which is called Genetic algorithm (GA). تفاصيل المقالة