Assessment of SPO2FRAG Software for Estimating Collapse Capacity of Steel Plate Shear Walls
الموضوعات :پویا آرزومند لنگرودی 1 , محمد رضا ادیب رمضانی 2 , عطا حجت کاشانی 3 , Saeed Farokhi Zadeh 4
1 - گروه مهندسی عمران، واحد تهران جنوب، دانشگاه آزاد اسلامی، تهران، ایران
2 - گروه مهندسی عمران ، واحد تهران جنوب ،دانشگاه آزاد اسلامی، تهران، ایران
3 - هیات علمی گروه مهندسی عمران- سازه و زلزله دانشکده فنی مهندسی دانشگاه آزاد اسلامی واحد تهران جنوب
4 - Assistant Professor, Department of civil Engineering, Islamic Azad University, south Tehran branch, Tehran, Iran
الکلمات المفتاحية: Steel plate shear wall, Pushover analysis, Fragility curve, Incremental dynamic analysis, Performance-based assessment,
ملخص المقالة :
Evaluating the seismic vulnerability and collapse capacity of structural systems typically involves conducting Incremental Dynamic Analysis (IDA) and generating fragility curves, both of which are complex and time-consuming. To simplify the extraction of fragility curves at different performance levels, the SPO2FRAG software was developed by previous researchers. However, its accuracy in predicting the collapse capacity of systems with varying heights has not been thoroughly validated against detailed analyses using seismic records. This study evaluates the efficiency and accuracy of SPO2FRAG in steel plate shear wall systems (SPSWs) with 4, 8, 12, and 16 stories, all designed in accordance with relevant codes. The numerical models were validated against a well-documented experimental specimen to ensure reliability. Fragility curves at the collapse performance level were derived using two methods: (1) IDA with 22 pairs of far-field earthquake records, and (2) the SPO2FRAG software he results show that for 4- and 8-story buildings, SPO2FRAG provides conservative estimates of collapse capacity compared to the more precise IDA. However, its reliability decreases with building height, leading to significant overestimation in the 16-story structure. While SPO2FRAG is a quick and cost-effective tool for assessing low- to mid-rise SPSWs, more accurate methods like IDA are recommended for taller structures. This study highlights the limitations of SPO2FRAG in evaluating taller SPSWs and underscores the importance of using detailed analysis methods for critical infrastructure. Future research should focus on enhancing the predictive capabilities of simplified tools like SPO2FRAG for high-rise structures.
[1]. FEMA P695 (2009). Quantification of building seismic performance factors, Washington, DC: Federal Emergency Management Agency.
[2]. Vamvatsikos, D. and Allin Cornell, C. (2006). Direct estimation of the seismic demand and capacity of oscillators with multi‐linear static pushovers through IDA. Earthquake Engineering & Structural Dynamics, 35(9), 1097-1117.
[3]. Ren, Y., Ma, D., Wang, W., Guo, X., Wang, Z., Chen, D., Wu, J., Fei, Z. and Zhao, X. (2024). Application of SPO2IDA in Seismic Performance Evaluation of Ancient Timber Structures. International Journal of Architectural Heritage, 18(8), 1308-1322. https://doi.org/10.1080/15583058.2023.2221215.
[4]. FEMA-P-58 (2012). Seismic performance assessment of buildings, Washington, D.C., USA: Federal Emergency Management Agency.
[5]. Baltzopoulos, G., Baraschino, R., Iervolino, I. and Vamvatsikos, D. (2017). SPO2FRAG: software for seismic fragility assessment based on static pushover. Bulletin of Earthquake Engineering, 15, 4399-4425. https://doi.org/10.1007/s10518-017-0145-3.
[6]. Yekrangnia, M. (2023). Seismic Vulnerability Assessment of Masonry Residential Buildings in the Older Parts of Tehran through Fragility Curves and Basic RVS Scores. Buildings, 13(2). https://doi.org/10.3390/buildings13020302.
[7]. Shanehsazzadeh, H., Tehranizadeh, M. and Haj Najafi, L. (2023). Evaluation of the Collapse Capacity Ratio of the Near Fault to the Far Fault and Its Effect on Collapse Risk in Terms of Pulse Period and Formability. Bulletin of Earthquake Science and Engineering, 10(3), 31-48. https://doi.org/10.48303/bese.2022.557180.1085.
[8]. Ugalde, D., Lopez-Garcia, D. and Parra, P. F. (2020). Fragility-based analysis of the influence of effective stiffness of reinforced concrete members in shear wall buildings. Bulletin of Earthquake Engineering, 18(5), 2061-2082. https://doi.org/10.1007/s10518-020-00786-3.
[9]. Kaveh, A., Mahdipour Moghanni, R. and Javadi, S. M. (2022). Chaotic optimization algorithm for performance-based optimization design of composite moment frames. Engineering with Computers, 38(3), 2729-2741. https://doi.org/10.1007/s00366-020-01244-z.
[10]. Sococol, I., Mihai, P., Petrescu, T.-C., Nedeff, F., Nedeff, V., Agop, M. and Luca, B.-I. (2022). Numerical Study Regarding the Seismic Response of a Moment-Resisting (MR) Reinforced Concrete (RC) Frame Structure with Reduced Cross-Sections of the RC Slabs. Buildings, 12(10), 1525. https://doi.org/10.3390/buildings12101525.
[11]. Mazzoni, S., McKenna, F., Scott, M. H. and Fenves, G. (2004). OpenSees users manual. PEER, University of California, Berkeley, 18, 56-57.
[12]. ANSI/AISC 341-22 (2022). Seismic Provisions for Structural Steel Buildings, Chicago (IL): American Institute for Steel Construction.
[13]. akbarpour, a., eftekhari, m. m. and Roudsari, M. T. (2023). Study of Scale Effect on Seismic Performance of Steel Plate Shear Wall under Cyclic Loading. International Journal of Advanced Structural Engineering, 4(13), 1-14. 10.30495/ijase.2023.708020.
[14]. Sabouri-Ghomi, S. and Sajjadi, S. R. A. (2012). Experimental and theoretical studies of steel shear walls with and without stiffeners. Journal of Constructional Steel Research, 75, 152-159. https://doi.org/10.1016/j.jcsr.2012.03.018.
[15]. Jalali, S. A. and Banazadeh, M. (2016). Development of a new deteriorating hysteresis model for seismic collapse assessment of thin steel plate shear walls. Thin-Walled Structures, 106, 244-257. https://doi.org/10.1016/j.tws.2016.05.008.
[16]. Arezoomand Langarudi, P., Adibramezani, M., Hojatkashani, A. and Farokhizadeh, S. (2024). Effect of Design Optimality and Overstrength on the Seismic Performance of Steel Plate Shear Walls. Iranian Journal of Science and Technology, Transactions of Civil Engineering. https://doi.org/10.1007/s40996-024-01513-7.
[17]. ASCE/SEI 7-22 (2022). Minimum design loads for buildings and other structures, Reston: American Society of Civil Engineering.
[18]. BahariPour, S., Nani, M., Hosseini, M., Moghadam, A. s. and Razzaghi, M. M. S. (2023). Performance Evaluation and Comparison of Schools with Masonry System Treated by Braces, FRP Strips and Friction Dampers Using Fragility Curves (Case Study: Khorram Abad). International Journal of Advanced Structural Engineering, 3(13), 0-0.
10.30495/ijase.2023.1992357.1075.
[19]. Vamvatsikos, D. and Cornell, C. A. (2002). Incremental dynamic analysis. Earthquake Engineering & Structural Dynamics, 31(3), 491-514. https://doi.org/10.1002/eqe.141.