Simultaneous Pre-Concentration of Cadmium and Lead in Environmental Water Samples with Dispersive Liquid-Liquid Microextraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
محورهای موضوعی :M. Salahinejad 1 , F. Aflaki 2
1 - Environmental Laboratory, NSTRI, Tehran, Iran
2 - Environmental Laboratory, NSTRI, Tehran, Iran
کلید واژه: Cd, Dispersive liquid-liquid microextraction, Pb, ICP-AES, environmental water,
چکیده مقاله :
The dispersive liquid–liquid microextraction (DLLME) method for determination of Pb+2 and Cd+2 ions in the environmental water samples was combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters included extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH, sample volume and amount of the chelating agent.  Under the optimum conditions, the enrichment factor of 75 and 105 for Cd+2 and Pb+2 ions respectively was obtained from only 5.00mL of water sample. The detection limit (S/N=3) was 12 and 0.8ngmL−1 for Pb and Cd respectively. The relative standard deviation (RSDs) for five replicate measurements of 0.50 mgL−1 of lead and cadmium was 6.5 and 4.4 % respectively. Mineral, tap, river, sea, dam and spiked water samples were analyzed for Cd and Pb amount.
- Fassett D.W., in Metals in the Environment,
- Academic Press, New York, 1980. pp 61-110.
- Patriarca M., A. Menditto, B. Rossi, T. D. B.
- Lyon, G. S. Fell, Environmental exposure to
- metals of newborns, infants and young children,
- Microchemical Journal, Volume 67, 2000. Pages
- -361.
- Hayes R.B., the carcinogenicity of metals in
- humans, Cancer Causes Control. 1997 May;
- (3):371-85.
- Bergbäck B., Carlsson M., Heritage of cadmium
- and lead, A case study of a Swedish accumulator
- factory. Sci Total Environ 166:35âââ42,1995.
- Bellinger D. C., Lead neurotoxicity and
- socioeconomic status: Conceptual and analytical
- issues. Neurotoxicology, 2008. 29: 828-32.
- Patocka J., K. Cerny, Inorganic Lead
- Toxicology, Acta Medica (Hradec Kralove), V. 46,
- No 2, 65-72, 2003.
- Waalkes M.P., Cadmium Carcinogenesis,
- Mutat.Res, 2003. 10:553,107-120
- Tellez-Plaza M., Navas-Acien A., Crainiceanu
- C. M., Cadmium exposure and hypertension in the
- - 2004 National Health and Nutrition
- Examination Survey (NHANES). Environmental
- Health Perspectives, 2008. 116: 51-6.
- International Agency for Research on Cancer
- (IARC) Monographs on the Evaluation of
- Carcinogenic Risks to Humans. Volume 58:
- Beryllium, Cadmium, Mercury, and Exposures in
- the Glass Manufacturing Industry. Summary of
- Data Reported and Evaluation. 1997. Available at
- http://
- www.monographs.iarc.fr/ENG/Monographs/vol58
- /volume58.pdf.Accessed May 1, 2008.
- Yang R.S.H., Goehl T. J. Brown R. D.,
- Chatham A. T., Arneson D. W., Buchanan R. C.,
- Harris R. K., 1989. Toxicological studies of a
- chemical mixture of 25 ground water
- contaminants. I. Chemistry development. Fundam.
- Appl. Toxicol. 13:366âââ376.
- Batterham G. J., N.C. Munksgaard , D. L.
- Parry, Determination of Trace Metals in Sea-water
- by Inductively Coupled Plasma Mass
- Spectrometry After Off-line Dithiocarbamate
- Solvent Extraction, J. Anal. At. Spectrom.,
- , 12, 1277 - 1280
- Li X., Schramel P., Wang Z., Grill P., Yedile
- A., Kettrup A., Determination of trace amounts of
- Sb, Pb, Tl in water samples by inductively coupled
- plasma atomic emission spectrometry after a
- diantipyrylmethane-iodide third phase
- preconcentration, Microchim. Acta, 124:171-178,
- Chen J., Xiao S., Wu X., Fang K., Liu W.,
- Determination of lead in water samples by
- graphite furnace atomic absorption spectrometry
- after cloud point extraction, Talanta, 67:992-996,
- Batterham G. J., Munksgaard N.C., Parry D.L.,
- Determination of Trace Metals in Sea-water by
- Inductively Coupled Plasma Mass Spectrometry
- After Off-line Dithiocarbamate Solvent Extraction,
- J. Anal. At. Spectrom., 1997. 12, 1277 âââ 1280.
- Mesquita R. B., Fernandes S. M. V., Rangel A.
- O. S., A flow system for the spectrophotometric
- determination of lead in different types of waters
- using ion-exchange for pre-concentration and
- elimination of interferences, Talanta 62:395-401,
- Dogan C. E., Akcin G., Solid Phase Extraction
- and Determination of Lead in Water Samples
- Using Silica Gel Homogeneously Modified by
- Thiosalicylic Acid, Anal Lett , 40: 2524-2543,
- Rezaee M., Assadi Y., Milani Hosseini M. R.,
- Aghaee E., Ahmadi F., Berijani S., Determination
- of organic compounds in water using dispersive
- liquid-liquid microextraction ,J chromatogr A
- :1-9, 2006.
- Fatahi N., Assadi Y., Milani Hosseini M. R.,
- Zeini Jahromi E., 2007. Determination of
- chlorophenols in water samples using
- simultaneous dispersive liquidâââliquid
- microextraction and derivatization followed by gas
- chromatography-electron-capture detection. J
- Chromatogr A 1157:23âââ29
- Berijani S., Assadi Y., Anbia M., Milani
- Hosseini M. R., Aghaee E., Dispersive liquidâââ
- liquid microextraction combined with gas
- chromatography-flame photometric detection:
- Very simple, rapid and sensitive method for the
- determination of organophosphorus pesticides in
- water, J Chromatogr A, 1123:1-9, 2006.
- Salahinejad M., Aflaki F., Optimization and
- determination of Cd (II) in different environmental
- water samples with dispersive liquidâââliquid
- microextraction preconcentration combined with
- inductively coupled plasma optical emission
- spectrometry, Environ. Monit. Assess. 177, 2011.
- -125
- Liang P., Sang H., Determination of trace lead
- in biological and water samples with dispersive
- liquidâââliquid microextraction preconcentration,
- Anal. Biochem. 380, 2008. 21âââ25
- Jiang H., Qin Y., Hu B., Dispersive liquid
- phase microextraction (DLPME) combined with
- graphite furnace atomic absorption spectrometry
- (GFAAS) for determination of trace Co and Ni in
- environmental water and rice samples, Talanta 74,
- 1160âââ1165.