Measuring the Concentration of Pollutant Particles PM2.5 and PM10 in Indoor Air of the Tehran International Exhibitions Company (TIEC)
Subject Areas : Air Pollutiondavoud adieh 1 , reza amirnezhad 2 , gholamreza Farid Fahimi 3 , Keyvan Saeb 4 , aptin rahnavard 5
1 - PhD Candidate in Environmental Pollution, Faculty of Environment, Tonekabon Branch, Islamic Azad University, Mazandaran, Iran.
2 - Assistant Professor, Department of Environment, Tonekabon Branch, Islamic Azad University, Mazandaran, Iran. *(Corresponding Author)
3 - Associate Professor, Department of Environment, Tonekabon Branch, Islamic Azad University, Mazandaran, Iran
4 - Assistant Professor, Department of Environment, Tonekabon Branch, Islamic Azad University, Mazandaran, Iran.
5 - Assistant Professor, Department of Environment, Tonekabon Branch, Islamic Azad University, Mazandaran, Iran.
Keywords: Indoor air pollution, Particulate Matters PM2.5, Particulate Matters PM10, Exhibition Sites.,
Abstract :
One of the most significant human health risks is the pollution of enclosed spaces. The high density of people and the variety of products available in exhibition halls make them perfect locations for the accumulation of polluting particles. Air pollutants are mixtures of suspended solids and liquids in the air, which vary in size, shape, and chemical composition.This study was conducted to measure PM2.5 and PM10 pollutants particles in four seasons consecutively throughout the year in Hall No. 38 of the Tehran International Exhibitions Company (TIEC). This goal was achieved by establishing an (SKC) air sampling pump at breathing height and comparing the results with the standard 24-hour analysis. According to the results, the average PM10 value in the autumn season was 160.8 µg cm-3, which was reported as higher than the standard 24-hour exposure value. There was also a maximum measured value of 198 µg cm-3 of PM10 during the mentioned season. The findings showed that the average PM2.5 value in the same season was 38 µg cm-3, which was reported as higher than the standard 24-hour exposure value (35 µg cm-3).It was mainly the effect of outdoor air quality on the indoor air in halls and the heating system that contributed to the increase in particulate matter in the autumn. According to the studies, it was found that outdoor and indoor air in halls is directly related. Therefore, Tehran Exhibition halls and other similar sites should continually monitor the level of air pollutants to reduce their health effects.
1. Landrigan PJ, Fuller R, Acosta NJ, Adeyi O, Arnold R, Baldé AB, et al.2018. The Lancet Commission on pollution and health. The Lancet 391(10119):462- 512.
2. Eira M, Prüss,Ustün A, Mudu P.2018. Reduce air pollution to beat NCDs: from recognition to action. The Lancet;392(10154):1178-79
3. Eric Breitung,2020. Indoor Air Quality in the Museum Environment. Workshop on the Indoor Air Quality in the Museum Environment. Department of Scientific Research The Metropolitan Museum of Art. New York, New York.
4. Sotiris, Vardoulakis., Evanthia, G., Susanne, S., Alice, D., Anne, S., Karen, S., & Ken, D., (2020). Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review. Int. J. Environ. Res. Public Health, 17, 8972.
5. Abdul-Wahab, S.A.; En, S.C.F.; Elkamel, A.; Ahmadi, L.; Yetilmezsoy, K. 2015. A review of standards and guidelines set by international bodies for the parameters of indoor air quality. Atmos. Pollut. Res. 2015, 5, 751–767.
6. Brauer, M.; Freedman, G.; Frostad, J.; van Donkelaar, A.; Martin, R.V.; Dentener, F.; van Dingenen, R.; Estep, K.; Amini, H.; Apte, J.S.; et al.2012. Exposure assessment for estimation of the global burden of disease attributable to outdoor air pollution. Environ. Sci. Technol. 2012, 45, 652–660.
7. Shruti Hegde, Kyeong T. Min, James Moore, Philip Lundrigan, Neal Patwari, Scott Collingwood, Alfred Balch4, Kerry E. Kelly,2020. Indoor Household Particulate Matter Measurements Using a Network of Low-cost Sensors. Aerosol and Air Quality Research, 20: 381–394.
8. Lam, N., K. Smith, A. Gauthier and M. Bates (2012). "KEROSENE: A REVIEW OF HOUSEHOLD.
9. Hoffmann, B.; Moebus, S.; Mohlenkamp, S.; Stang, A.; Lehmann, N.; Dragano, N.; Schmermund, A.; Memmesheimer, M.; Mann,K.; Erbel, R.; et al,2007. Residential exposure to traffic is associated with coronary atherosclerosis. Circulation, 116, 489–496
10. Hassanvand, M.S.; Naddafi, K.; Faridi, S.; Arhami, M.; Nabizadeh, R.; Sowlat, M.H.; Pourpak, Z.; Rastkari, N.; Momeniha, F.;Kashani, H.; et al. 2014. Indoor/outdoor relationships of PM10, PM2.5, and PM1 mass concentrations and their water-soluble ions in a retirement home and a school dormitory. Atmos. Environ., 82, 375–382.
11. Adams, K.; Greenbaum, D.S.; Shaikh, R.; van Erp, A.M.; Russell, A.G.2015. Particulate matter components, sources, and health:Systematic approaches to testing effects. J. Air Waste Manag. Assoc.2015, 65, 544–558.
12. Karagulian, F.; Belis, C.A.; Dora, C.F.C.; Pruss-Ustun, A.M.; Bonjour, S.; Adair-Rohani, H.; Amann, M. . 2015 .Contributions to cities’ambient particulate matter (PM): A systematic review of local source contributions at global level. Atmos. Environ, 120,475–483.
13. Shruti Hegde, Kyeong T. Min, James Moore, Philip Lundrigan, Neal Patwari, Scott Collingwood, Alfred Balch4, Kerry E. Kelly,2020. Indoor Household Particulate Matter Measurements Using a Network of Low-cost Sensors. Aerosol and Air Quality Research, 20: 381–394.
14. WHO,Europe,2011. Methods for monitoring indoor air quality in schools. Report from the meeting 4-5 April 2011.Bonn, Germany.
15. Chiara, Civardi.2019.Making industrial exhibitions green A literature research on the LCA of physical and virtual industrial exhibitions.
16. Bolourchi, Ameneh., Atabi, F ., Moatar, F., & Ehyayee, M., (2018). Investigation on the Concentration of Suspended Particulate Matters in Tehran Underground Subway Stations and Compare it with Ambient Concentrations. Environmental science and technology. 22th, No,6. (In Persian)
17. Chang, S.C., Chou, C.C.K., Chan, C.C. and Lee, C.T., 2010. Temporal characteristics from continuous measurementsof PM2.5 and speciation at the Taipei aerosol supersite from 2002 to 2008. Atmospheric Environment. Vol 44, pp. 1088-1096
18. Gyu-Sik Kim, Youn-Suk Son, Jai-Hyo Lee, In-Won Kim, Jo-Chun Kim,2016. Air Pollution Monitoring and Control System for Subway.Stations Using Environmental Sensors. Hindawi Publishing Corporation.Journal of Sensors.Volume 2016, Article ID 1865614, 10 pages.
19. Ghiyasodin, Mansor., Atabi, F., Hesami, Z., & Mahmodi, M., (2006). Investigating the air quality inside residential houses in District 1 and 5 of Tehran city in terms of airborne particles (PM10). Journal of Environment. Year 32, Number 40, Pages 1-8. (In Persian)
20. Ling Zhang, Changjin O, , Dhammika M, Meththika, V, Kanth ,S .2021. Indoor Particulate Matter in Urban Households:Sources, Pathways, Characteristics, Health Effects,and Exposure Mitigation. Int. J. Environ. Res. Public Health, 18, 11055.