Surveying of Changes in the Frequency of Products Bubbles in the Solution of Pure Acetone and Pure Water on the Heater Brass
Subject Areas : The Application of Chemistry in Environment
Keywords: Heat Transfer Coefficient, rough, conversion, surface substance,
Abstract :
In this article, the frequency of products bubble boiling lacustrine saturated in pure acetone and water in term of heat flux in range of 1000 to 75000 assigned watt per square meter on horizontal cylindrical Brass were studied and it was found the solution that was better at frequencies produce bubbles. Experimental data were compared with existing models, Fault models were calculated and shown that Hatton and Hall Models for pure acetone and Ivey model in pure water had been lowest fault and Macfadden model had the most fault estimated for both solutions in comparison with experimental data.
_||_