Power management of a wind energy conversion system equipped by DFIG
Subject Areas : Renewable energyIman Zangiabadi 1 , Afshin Etesami 2
1 - Ms.C.- Head of Enginrring and Supervision Sarcheshmeh Industrial Power Co., Kerman, Iran
2 - Instructor-Department of Electrical Engineering, Islamic Azad University, Najafabad Branch
Keywords: Harmonic, Power Quality, Doubly Fed Induction Generator, Rotor side convertor, Grid side convertor,
Abstract :
Today wind is one of the attractive points of energy area which has got the noticeable amount of investment and studies in this field. Considering the importance of the wind energy and its potentials as one of the renewable energy sources, in this paper managing the production of active and reactive powers of a wind energy conversion system equipped with DFIG has been studied. In this regard, a structure based on vector control is offered to achieve an independent control of active and reactive powers. The strategy of managing the production of active and reactive power is applied to network by rotor side converter of a DFIG. The production of active power according to the maximum power point taking (MPPT) strategy to get a maximum power of the wind energy has been done and also improvement of power quality based on strategies of power factor correction and harmonics reduction have been arranged for a power network. In order to evaluate the performance of the proposed method, a DFIG connected with a power network in different conditions of the reactive load has been simulated by MATLAB software.Obviously, the results state the proper operation of the power control of wind energy converting system , improvement of the network power factor, and Reduction of harmonic current of network based on the proposed method.
[1] G. Shahgholian, "PID controller design for load-frequncy control in power system with hydro-turbine includes trinsient droop compensation", Dam and Hedroelectric Powerplant, Vol. 2, No. 5, pp. 50-64, 2015 (in Persian).
[2] M. Mahdavian, G. Shahgholian, M. Janghorbani, B. Soltani, N. Wattanapongsakorn, "Load frequency control in power system with hydro turbine under various conditions", Proceeding of the IEEE/ECTICON, pp. 1-5, Hua Hin, Thailand, June 2015.
[3] J. Mohammadi, S. Vaez-Zadeh, S. Afsharnia, E. Daryabeigi, "A combined vector and direct power control for DFIG-based wind turbines", IEEE Trans. on Sustainable Energy, Vol. 5, No. 3, pp. 767-775, June 2014 .
[4] M. Fooladgar, E. Rok-Rok, B. Fani, Gh. Shahgholian, "Evaluation of the trajectory sensitivity analysis of the DFIG control parameters in response to changes in wind speed and the line impedance connection to the grid DFIG", Journal of Intelligent Procedures in Electrical Technology, Vol. 5, No. 20, pp. 37-54, winter 2015 (in Persian).
[5] M. Mohseni, S.M. Islam, M.A.S. Masoum, "Enhanced hysteresis-based current regulators in vector control of DFIG wind turbines", IEEE Trans. on Power Electronics, Vol. 26, No. 1, pp. 223-234, Jan. 2011.
[6] G. Shahgholian, N. Izadpanahi, "Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller", Energy Equipment and Systems, Vol. 4, No. 1, pp. 65-79, June 2016.
[7] G. Shahgholian, K. Khani, M. Moazzami, "The Impact of DFIG based wind turbines in power system load frequency control with hydro turbine", Dam and Hedroelectric Powerplant, Vol. 1, No. 3, pp. 38-51, Winter 2015 (in Persian).
[8] A. Gaillard, P. Poure, S. Saadate, M. Machmoum, "Variable speed DFIG wind energy system for power generation and harmonic current mitigation", Renewable Energy, Vol. 34, No. 6, pp. 1545-1553, June 2009.
[9] M.T. Abolhassani, P. Enjeti, H.A. Toliyat, "Integrated doubly fed electric alternator/active filter (IDEA), a viable power quality solution for wind energy conversionsystems", IEEE Trans. on Energy Conversion, Vol. 23, No. 2, pp. 642-650, June 2008.
[10] M. Singh, A. Chandra, "Application of adaptive network-based fuzzy inference system for sensorless control of PMSG-based wind turbine with nonlinear-load-compensation capabilities", IEEE Trans. on Power Electronics, Vol. 26, No. 1, pp.165-175, Jan. 2011.
[11] A.K. Jain, V.T. Ranganathan, "Wound rotor induction generator with sensorless control and integrated active filter for feeding nonlinear loads in a stand-alone grid", IEEE Trans. on Industrial Electronics , Vol. 55, No. 1, pp. 218-228, Jan. 2008.
[12] M.Singh, V. Khadkikar, A. Chandra, "Grid synchronisation with harmonics and reactive power compensation capability of a permanent magnet synchronous generator-based variable speed wind energy conversion system", IET Power Electronics, Vol. 41, No. 1, pp. 122-130, Jan 2011.
[13] Z. Chen, "Compensation schemes for a SCR converter in variable speed wind power systems", IEEE Trans. on Power Delivery, pp. 813-821, Vol. 19, No. 2, April 2004.
[14] S. Engelhardt, S.I. Erlich, C. Feltes, J. Kretschmann, F. Shewarega, "Reactive power capability of wind turbines based on doubly fed induction generators", IEEE Trans. on Energy Conversion, Vol. 26, No. 1, pp. 364-372, March 2011.
[15] M. Kayikçi, J. Milanovic, "Reactive power control strategies for DFIG-based plants”, IEEE Trans. on Energy Conversion, Vol. 22, No. 2, pp. 389-396, June 2007.
[16] M. Machmoum, A. Hatoum, T. Bouaouiche, "Flicker mitigation of a doubly-fedinduction generator for wind energy conversion system”, Mathematics andComputers in Simulation, Vol. 81, No. 2, pp. 433-445, Oct. 2010.
[17] M. Boutoubat, L. Mokrani, M. Machmoum, "Control of a wind energy conversion system equipped by a DFIG for active power generation and power quality improvement", Renewable Energy, Vol. 50, pp. 378-386, Feb. 2013.
[18] R.M. Linus, P. Damodharan, "Maximum power point tracking method using a modified perturb and observe algorithm for grid connected wind energy conversion systems", IET Renewable Power Generation, Vol. 9, No. 6, pp. 682-689, Aug. 2015.
[19] N. Ramesh-Babu, P. Arulmozhivarman, " Wind energy conversion systems: A technical review", Journal of Engineering Science and Technology, Vol. 8, No. 4, pp. 493 – 507, 2013.
[20] G. Shahgholian, K. Khani, M. Moazzami, "Frequency control in autonomous microgrid in the presence of DFIG based wind turbine", Journal of Intelligent Procedures in Electrical Technology, Vol. 6, No. 23, pp. 3-12, Autumn 2015 (in Persian).
[21] M. Boutoubat, L. Mokrani, M. Machmoum, F. Auger, "Selective harmonics compensation using a WECS equipped by a DFIG", Proceeding of the IEEE/IECON, pp. 745-750, Montreal, QC, Oct. 2012.
[22] V. Kumar, M. Bajaj, A. Kumar, "Power electronics converters for a wind energy conversion system: Review”, International Journal of Scientific and Engineering Research, Vol. 4, No. 6, pp. 2686-2693, June 2013.
[23] S. Vanukuru, S. Sukhavasi, "Active & reactive power control of a doubly fed induction generator driven by a wind turbin", International Journal of Power System Operation and Energy Management, Vol. 1, No. 2, 2011.
[24] M. Machmoum, M. Boutoubat, L. Mokrani, "Power quality improvement using grid side converter of wind energy conversion system", Journal of Energy and Power Engineering , Vol. 7, pp. 752-759, 2013.
[25] H. Akangi, Y. Kanazawa, A. Nabae, "Instantaneous reactive power compensators comprising switching devices without energy storage components", IEEE Trans. on Industry Applications, Vol. IA-20, No. 3, May/June 1984.
[26] E. Daryabeigi, B. Mirzaeian-Dehkordi, "Smart bacterial foraging algorithm based controller for speed control of switched reluctance motor drives", International Journal of Electrical Power and Energy Systems, Vol. 62, pp. 364–373, Nov. 2014.