Investigating the Impact of Exterior Window Shutters on Indoor Climate Conditions in Humid and Temperate Climate
Subject Areas : Built EnvironmentMilad karimi 1 , Shahin Heidari 2 , Seyed Majid Mofidi Shemirani 3
1 - Department of Art and Architecture, West Tehran Branch, Islamic Azad University ,Tehran, Iran.
2 - Department of Architecture, University of Tehran, Tehran, Iran.
3 - Department of Architecture, Iran University of Science and Technology, Tehran, Iran.
Keywords:
Abstract :
Bagarić, M., Banjad Pečur, I., & Milovanović, B. (2020). Hygrothermal performance of ventilated prefabricated sandwich wall panel from recycled construction and demolition waste – A case study. Energy and Buildings, 206, 109573.
Desta, T. Z., Langmans, J., & Roels, S. (2011). Experimental data set for validation of heat, air, and moisture transport models of building envelopes. Building and Environment, 46(5), 1038-1046.
Gao, C. F., & Lee, W. L. (2011). Evaluating the influence of openings configuration on natural ventilation performance of residential units in Hong Kong. Building and Environment, 46(4), 961-969.
Ghiabaklou, Z. (2013). Fundamentals of Building Physics 4: Passive Cooling [Fundamentals of Building Physics 4 - Passive Cooling]. Publication of Jihad Amirkabir University. "Persian"
Glass, S., TenWolde, A., & Zelinka, S. (2013). Hygrothermal Simulation: A Tool for Building Envelope Design Analysis. Wood Design Focus, 23,18-25.
Golabchi, M., Andaji Garmaroodi, A., & Bastani, H. (2012). Digital Architecture: CAD/CAM/CAE Technologies Application in Architecture (2nd ed.). University of Tehran Press. "Persian"
Karagiozis, A. (2020). Impact of Air Leakage on the Thermal and Moisture Performance of the Building Envelope in Conference: Air Barriers III: Air Barrier Solutions for Buildings in North American Climates, United States.
Karagiozis, A., & Salonvaara, M. (2001). Hygrothermal system performance of a whole building. Building and Environment, 36, 779-787.
Kasmai, M. (2003). Climate and Architecture (M. Ahmadinezhad, Ed. 2nd ed.), Isfahan: Khak publication. "Persian"
Košir, M. (2016). Adaptive Building Envelope: An Integral Approach to Indoor Environment Control in Buildings. In Automation and Control Trends.
Le, A. D. T., Samri, D., Rahim, M., Douzane, O., Promis, G., & Langlet, T. (2015). Effect of Temperature-dependent Sorption Characteristics on The Hygrothermal Behavior of Hemp Concrete. Energy Procedia, 78, 1449-1454.
Montalbán Pozas, B., & Neila González, F. J. (2016). Hygrothermal behaviour and thermal comfort of the vernacular housings in the Jerte Valley (Central System, Spain). Energy and Buildings, 130, 219-227.
Parker, P., & Lozinsky, C. (2010). Thermal and hygrothermal analysis in building envelope commissioning. In NIBS Building Enclosure Science & Technology Conference. National Institute of Building Sciences (NIBS) (pp. 12-14).
Galogahi, S. Z., Majidaee, M., Beheshti, H. M., & Alishah, M. (2016). Effects of window position on natural cross ventilation in vernacular architecture of Mazandaran (Case study: Sari). Journal of Fundamental and Applied Sciences, 8(2), 567-586.
Salonvaara, M., & Ojanen, T. (2003). Indoor Air Humidity Variations And Its Effects On The Moisture Performance Of Building Envelopes. Building Simulation, 8, 1163-1170
Shahin, H. S. M. (2019). Adaptive building envelopes of multistory buildings as an example of high-performance building skins. Alexandria Engineering Journal, 58(1), 345-352.
Soltanzadeh, H., & Ghaseminia, M. (2016). Climatic Building Envelope Employed In Vernacular Residential Architecture In Golestan-Iran. International Journal of Architecture and Urban Development, 6(1 (19)), -.
Paepe, M., & Janssens, A. (2010). Impact of whole-building hygrothermal modelling on the assessment of indoor climate in a library building. Building and Environment, 45(7), 1641-1652.
Tadeu, A., Škerget, L., Simões, N., & Fino, R. (2018). Simulation of heat and moisture flow through walls covered with uncoated medium-density expanded cork. Building and Environment, 142, 195-210.