        1 - Antioxidant Properties of Ajwain using Square wave, Cyclic voltammetry methods and DPPH method
        Zahra khoramian Mohammad Hadi Givianrad Hessam Sepasi Tehrani
        Ajwain is one of the medicinal plants, which the highest composition is thymol, as a strong antioxidant respect to the obtained chromatograms of GC/MS. The antioxidant activity of the Ajwain is measured by square wave voltammetry method and cyclic voltammetry method and أکثر
        Ajwain is one of the medicinal plants, which the highest composition is thymol, as a strong antioxidant respect to the obtained chromatograms of GC/MS. The antioxidant activity of the Ajwain is measured by square wave voltammetry method and cyclic voltammetry method and 2, 2-Diphenyl-1-picrylhydrazyl (DPPH) method in at the specific concentrations of 1%, 1.5%, 2% and 2.5% and constant pH. The results of the present study indicated that the antioxidant activity of Ajwain obtained from cyclic voltammetry and square wave is almost equal to the results of the DPPH method, which can be used to measure the antioxidant activity. Compared to DPPH method, electrochemical method involves a number of advantages such as simplicity, cheap operating costs, fastness, low amount of solvent, and no need for chemical reagents. Furthermore, based on the results obtained, the square wave method includes a higher sensitivity and accuracy than cyclic voltammetry method and DPPH method. تفاصيل المقالة
      • حرية الوصول المقاله

        2 - Evaluation of the antioxidant activity of Thymus Using Electrochemical Methods and radical scavenging method
        Amir Yousefi Mohammad Hadi Givianrad Hessam Sepasi Tehrani
        Thymus is regarded as one of the medicinal species, which according to obtained chromatograms of floral water of Thymus; one of the main components is thymol as strong antioxidant. In this study the appropriate and physically powerful correlation was found between the a أکثر
        Thymus is regarded as one of the medicinal species, which according to obtained chromatograms of floral water of Thymus; one of the main components is thymol as strong antioxidant. In this study the appropriate and physically powerful correlation was found between the anti-radical and oxidation potentials. The antioxidant activity of the Thymus was measured by using square wave and cyclic voltammetry methods and 2, 2-diphenyl-1-picrylhydrazyl hydrate (DPPH) method in the concentration range of 1% to 2.5% V/V. Electrochemical methods are used based on the relationship between oxidation power and antioxidant strength, which compared with ascorbic acid as standard. Based on the results of electrochemical methods, these methods have several advantages over the DPPH∙ method such as simplicity, cheaper operating costs, short integration time, high speed, low solvent and sample usage. Moreover, the square wave voltammetry method is more sensitive method for evaluation the antioxidant activities compared to DPPH and cyclic voltammetry methods. تفاصيل المقالة
      • حرية الوصول المقاله

        3 - Electrochemical Study of Encapsulated Heteropolyacids in Acidic Mordenite Zeolite
        M. Arvand A. Islamnezhad M.A. Zanjanchi
        12-molybdophosphoric acid (PMo12) was encaged into HMOR zeolite by “ship in a bottle”method in aqueous phase which is strongly retained and not easily leached from the host channels.The solid was characterized by XRD prior to using it for the electrode prepa أکثر
        12-molybdophosphoric acid (PMo12) was encaged into HMOR zeolite by “ship in a bottle”method in aqueous phase which is strongly retained and not easily leached from the host channels.The solid was characterized by XRD prior to using it for the electrode preparation. This compoundwas incorporated with a carbon paste electrode for cyclic voltammetric measurements. PMo12immobilized on the support underwent a quasi-reversible electrochemical redox reaction. Invarious electrolyte solutions and also changing the pH range from 0 to 5, the ΔEp remainspractically constant, i.e. 179mV. The comparison of these voltammograms with those in aqueousphase shows remarkable similarities, therefore it is may concluded that this hybrid material hasredox catalytic properties and high surface area, simultaneously. تفاصيل المقالة
      • حرية الوصول المقاله

        4 - ارزیابی سطح آلودگی به جیوه در کپسول های روغن ماهی امگا- 3 استحصالی از ماهی های راسته کوسه و تن عرضه شده در شهر تهران به روش ولتامتری چرخه ای
        بهروز اکبری آدرگانی لطیفه نویدپور مریم شکرچی
        روغن ماهی سرشار از اسیدهای چرب مفید است. امروزه استفاده از روغن ماهیامگا- 3 به دلیل اثرات مفید آن بر سلامت انسان مصرف بیشتری پیدا کرده است.امروزه به دلیل فعالیت های صنعتی، انتشار جیوه و ترکیبات آن به محیط زیادشده و به دلیل خطر برای سلامت انسان نگرانی هایی در مورد بروز آ أکثر
        روغن ماهی سرشار از اسیدهای چرب مفید است. امروزه استفاده از روغن ماهیامگا- 3 به دلیل اثرات مفید آن بر سلامت انسان مصرف بیشتری پیدا کرده است.امروزه به دلیل فعالیت های صنعتی، انتشار جیوه و ترکیبات آن به محیط زیادشده و به دلیل خطر برای سلامت انسان نگرانی هایی در مورد بروز آلودگیجیوه در روغن ماهی وجود دارد. هدف اصلی این تحقیق ارزیابی سطح آلودگیکپسول های روغن ماهی امگا- 3 به جیوه در سطح عرضه در شهر تهران به روشولتامتری چرخه ای است. بدین منظور 14 نمونه تجاری روغن ماهی از سطحشهر تهران جمع آوری و به آزمایشگاه منتقل شد. در این تحقیق از روش آمادهسازی هضم میکروویو و آنالیز ولتامتری چرخه ای برای تعیین مقدار جیوه استفادهگردید. فرآیند هضم در فشار ثابت 50 بار و شیب دمایی 145 تا 200 درجهسانتی گراد طی چهار مرحله انجام شد. نتایج این بررسی نشان داد که غلظت جیوه در 14 نمونه روغن ماهی مورد بررسی در دامنه 11/03 تا 107/11 نانوگرم بر میلی لیتر بوده است( Pاز راسته کوسه ماهی و ماهی تن که مستعد تجمع جیوه هستند می تواند سلامتمصرف کننده را دچار مخاطره جدی کند. تفاصيل المقالة
      • حرية الوصول المقاله

        5 - Binuclear Complex of Zinc and Copper with Unsymmetrical Macrocyclic Ligand as Sensitizer in Nanocrystaline TiO2 Solar Cells
        Malihe Khalili Mohammad Abedi Davood Sadeghi Fateh Kobra Razmi
        Dye sensitized solar cells (DSSCs) are considered as one of the most promising alternativerenewable energy sources. In the structure of DSSCs, a photosensitizer composed of transitionmetal complexes is used to harvest light. In this work a binuclear complex containing t أکثر
        Dye sensitized solar cells (DSSCs) are considered as one of the most promising alternativerenewable energy sources. In the structure of DSSCs, a photosensitizer composed of transitionmetal complexes is used to harvest light. In this work a binuclear complex containing twopropionitrile pendant arms [ZnLCu(OAC)]PF6 {L = 1, 6- bis (2-cyanoethyl) -2, 5-bis (2-hydroxy3-formyl-5-methylbenzyl)-2, 5- diazahexane} has been examined as a non-planar metal basedphotosensitizer in the fabrication of dye sensitized solar cell. The photovoltaic performance ofthe fabricated cell was evaluated and photovoltaic parameters were determined. The resultsshowed the conversion efficiency of 0.17%, current density of (Jsc) 0.69 mAcm-2, voltage (Voc)0.38 v and fill factor (FF) of 0.69 under sun (Am1.5) for the cells. Electrochemical impedancespectroscopy (EIS) and cyclic voltammetry (CV) were employed to study the electron transfermechanism in fabricated cells. The results showed that the potential in cathodic current was morepositive indicating that the conduction band position of TiO2 had shifted to positive energiesconfirming less Voc of the fabricated cell. تفاصيل المقالة
      • حرية الوصول المقاله

        6 - Determination of Acetaminophen Via TiO2/MWCNT Modified Electrode
        Ali Asghar Pasban Elham Hossein Nia Masoumeh Piryaei
        Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement أکثر
        Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the unmodified glassy carbon electrode, the peak currents were enhanced significantly by 8.5 folds (oxidation peak) and 11.0 folds (reduction peak), which showed stable response with enhanced selectivity and sensitivity. A linear calibration plot having a correlation coefficient of 0.991 was obtained in the concentration range of 0.01-0.12 mM acetaminophen. The detection limit for the detection of acetaminophen was calculated as 11.77 μM based on 3 σ/m. The method was applied in the determination of acetaminophen in commercial tablets. The recoveries of the composite modified electrode obtained were 95.2 and 96.2% for five determinations. تفاصيل المقالة
      • حرية الوصول المقاله

        7 - کاهش الکتروشیمیایی گرافن اکسید با روش‏ های ولتامتری چرخه ‏ای و پتانسیل ثابت بر زیرلایه مس
        مجید میرزایی چنگیز دهقانیان
        در این پژوهش گرافن اکسید با روش های ارزان قیمت و سازگار با محیط‎زیست بر زیرلایه مس کاهش یافت. این روش ها شامل پتانسیل ثابت و ولتامتری چرخه ای بود. در روش ولتامتری چرخه ای گرافن اکسید بر زیرلایه مس رسوب نشانی شد و کاهش یافت و در روش پتانسیل ثابت ابتدا به روش قطره أکثر
        در این پژوهش گرافن اکسید با روش های ارزان قیمت و سازگار با محیط‎زیست بر زیرلایه مس کاهش یافت. این روش ها شامل پتانسیل ثابت و ولتامتری چرخه ای بود. در روش ولتامتری چرخه ای گرافن اکسید بر زیرلایه مس رسوب نشانی شد و کاهش یافت و در روش پتانسیل ثابت ابتدا به روش قطره چکانی، گرافن اکسید رسوب نشانی شد و سپس با روش پتانسیل ثابت کاهش یافت. گرافن اکسید کاهش‎یافته با میکروسکوپ الکترونی پویشی (SEM) و طیف‎شناسی فوتوالکترون پرتو ایکس (XPS) و رامان مشخصه یابی شد. نتیجه ها نشان داد که روش پتانسیل ثابت، بهترین روش در کاهش گرافن اکسید است و بیشینه گروه های عاملی کاهش‎یافته و بیشینه چگالی نواقص و چروکیدگی صفحه ها را به خود اختصاص داد. طیف‎شناسی رهبندی الکتروشیمیایی (EIS) نیز ثابت کرد که بیشینه رسانایی متعلق به گرافن اکسید یافته با روش پتانسیل ثابت است. درنتیجه این روش می تواند جایگزین روش های شیمیایی برای کاهش گرافن اکسید شود و ضعف عمده روش های شیمیایی را که استفاده از مواد سمی در کاهش است، برطرف کند. تفاصيل المقالة
      • حرية الوصول المقاله

        8 - تهیه یک کاتالسیت ساده و ارزان با الکترود خمیر کربن اصلاح‌شده با سدیم دودسیل سولفات دارای نیکل برای اکسایش الکتروکاتالیستی اتیلن گلیکول
        بنفشه نوروزی زهرا شاکری
        در این کار پژوهشی، سدیم دودسیل سولفات (SDS) به روش قطره‌گذاری در سطح الکترود خمیر کربن قرار گرفت. سپس با قرار دادن الکترود اصلاح‌شده در محلول حاوی نیکل نیترات به مدت 5 دقیقه و روبش متوالی پتانسیل در محلول سدیم هیدروکسید، الکترود خمیر کربن اصلاح‌شده با SDS دارای نیکل (Ni أکثر
        در این کار پژوهشی، سدیم دودسیل سولفات (SDS) به روش قطره‌گذاری در سطح الکترود خمیر کربن قرار گرفت. سپس با قرار دادن الکترود اصلاح‌شده در محلول حاوی نیکل نیترات به مدت 5 دقیقه و روبش متوالی پتانسیل در محلول سدیم هیدروکسید، الکترود خمیر کربن اصلاح‌شده با SDS دارای نیکل (Ni/SDS) تهیه شد. همچنین، با توجه به اهمیت به‌کارگیری اتیلن گلیکول به‌عنوان منبع پیشنهادی جایگزین هیدروژن و به دلیل سینتیک کند آن در سطح الکترودهای خمیر کربن اصلاح‌نشده، اکسایش آن در سطح الکترود اصلاح‌شده فوق بررسی شد. نتایج به‌دست آمده بیانگر اکسایش الکتروکاتالیستی اتیلن گلیکول در سطح الکترود خمیر کربن اصلاح‌شده با Ni/SDS است. تأثیر عامل‌های متفاوت بر مقدار کارایی الکترود اصلاح‌شده بررسی و شرایط بهینه تعیین شد. در پایان نیز ثابت سرعت واکنش شیمیایی بین مراکز ردوکس در سطح الکترود اصلاح‌شده و اتیلن گلیکول محاسبه شد. سادگی، ارزانی و حساسیت بالا ازجمله ویژگی‌های برجسته این الکترود است. تفاصيل المقالة
      • حرية الوصول المقاله

        9 - بررسی سنتیکی و مطالعه طول عمر مواد 5-برومو-2-(((1-هیدروکسی‌بوتان-2-ایل)ایمینو)متیل)فنل و 2-((2-((2-هیدروکسی‌بنزیلیدن)آمینو)اتیل)آمینو)فنل به‎عنوان بازدارنده‌های خوردگی با روش‎های الکتروشیمیایی نوین تبدیل فوریه سریع
        محسن مرکزی جواد شعبانی شایه بهنام راسخ
        خوردگی فلزها از دیرباز عامل مهمی در تحمیل خسارت به همه صنایع بوده که روش های متفاوتی از جمله کاربرد علم الکتروشیمی و بازدارنده های خوردگی در کشف و جلوگیری از آن موثر بوده است. یکی از نکته های مهمی که در مورد بازدارنده های خوردگی باید توجه داشت، طول عمر سینتیک بازدارندگی أکثر
        خوردگی فلزها از دیرباز عامل مهمی در تحمیل خسارت به همه صنایع بوده که روش های متفاوتی از جمله کاربرد علم الکتروشیمی و بازدارنده های خوردگی در کشف و جلوگیری از آن موثر بوده است. یکی از نکته های مهمی که در مورد بازدارنده های خوردگی باید توجه داشت، طول عمر سینتیک بازدارندگی آن ها است. در این پژوهش، عملکرد دو نوع بازدارنده به‎نام های 5-برومو-2-(((1-هیدروکسی بوتان-2-ایل)ایمینو)متیل)فنل (C11H14BrNO2) و 2-((2-((2-هیدروکسی بنزیلیدن)آمینو)اتیل)آمینو)فنل (C15H16N2O2) از نظر سینتیکی و مقدار طول عمر مفید بازدارندگی در کاهش نرخ خوردگی فولاد آلیاژ A106 Gr.b به‎کارگرفته‎شده در خطوط لوله انتقال نفت در محیط خورنده سولفوریک اسید یک میلی‎مولار مورد بررسی شد. مقایسه بین این دو بازدارنده و نقش عنصر نیتروژن در عملکرد این دو و ماندگاری آن ها در محیط به کمک روش الکتروشیمیایی تبدیل فوریه سریع برای پردازش داده ها مورد بررسی قرار گرفت. نتیجه‎ها نشان داد که بازدارنده C11H14BrNO2 با داشتنن سینتیک آهسته تر در روند تجزیه برای مدت طولانی تر در محیط باقی می‎ماند و نسبت به عمل مهار خوردگی موثرتر واقع می شود. همچنین، این بازدارنده باوجود داشتن یک عنصر نیتروژن کمتر در ساختار خود، به ‎علت داشتن ساختار فضایی مساعدتر و قراردهی بهتر آن عنصر در سطح فلز مورد خوردگی، عملکرد بسیار مناسب تری در مهار خوردگی فولاد دارد. تفاصيل المقالة
      • حرية الوصول المقاله

        10 - Electrochemical behaviour of lead in hydrochloric acid solution in the presence of inorganic ions
        Belkheir Hammouti Rachid Salghi Mohammed Mihit Lahcen Bazzi
        The electrochemical behaviour of lead electrode in hydrochloride solution containing variousoxo-anions at different concentrations was studied by using of cyclic voltammetry (CV) method.Results obtained show that the addition of these inorganic compounds decreases the a أکثر
        The electrochemical behaviour of lead electrode in hydrochloride solution containing variousoxo-anions at different concentrations was studied by using of cyclic voltammetry (CV) method.Results obtained show that the addition of these inorganic compounds decreases the anodic andcathodic currents peaks according to the following order: H2PO4- > HPO42-> SO42-. It’s revealedalso that the cathodic current density related to the reduction of Pb2+ ions dissolved in solutiondecreases with the oxo-anions concentration. When the addition of sulphates ions concentrationreaches 0.34 mol L-1, the formation of PbSO4 is highly favoured. Therefore, the intersticesbetween the crystals of PbSO4 encourage the dissolution of lead and the formation of insolublePbCl2 layer on the lead surface involving the passivation phenomenon. تفاصيل المقالة
      • حرية الوصول المقاله

        11 - Cu(II) and Zn(II) complexes with unsymmetrical tetradentate Schiff base ligands: Synthesis, spectral characterization, antimicrobial assay and DNA binding property
        Natarajan Raman Rajkumar Mahalakshmi Abraham Selvan Muthusamy Selvaganapathy
        The reaction of copper(II) chloride and zinc(II) chloride with N-(2-methylphenyl)-3-(1'-salicylaldehydene-2'-imine-ethane)-butanamide(H2L2a) or (MPSB), N-(2-methylphenyl)-3-(1'-(3'-methoxysalicylaldehydene-2'-imine-ethane)-butanamide (H2L2b) or (MPMSB) and N-(2-methylph أکثر
        The reaction of copper(II) chloride and zinc(II) chloride with N-(2-methylphenyl)-3-(1'-salicylaldehydene-2'-imine-ethane)-butanamide(H2L2a) or (MPSB), N-(2-methylphenyl)-3-(1'-(3'-methoxysalicylaldehydene-2'-imine-ethane)-butanamide (H2L2b) or (MPMSB) and N-(2-methylphenyl)-3-(1'-(2'-hydroxyacetylene-2'-imine-ethane)-butanamide (H2L2c) (MPHB) leads to the formation of a series of new complexes and theyhave been characterized by the spectral and analytical techniques. For the complexes [CuL2a-c] and [ZnL2ac],the central metal ion is coordinated to two azomethine nitrogen atoms and one phenolic oxygen atom ofthe aromatic aldehydes as well as 2-hydroxyacetophenone and enolic oxygen atom of the 2'-methylacetoacetanilide. DNA binding studies reveal the stronger binding capability of the present copper(II)complexes, confirmed by the absorbance, cyclic voltammetry, differential pulse voltammogram andviscometric studies. Similarly, remaining complexes do the same in the ligand field with less bindingconstants. In addition, fungistatic and bacteriostatic activities of both ligands and complexes have beenevaluated. copper(II) complexes have shown the most significant activities. تفاصيل المقالة