Optimization of FACTS devices to reduce losses in transmission networks using HSA
الموضوعات :
1 - Department of Computer Engineering, Yasouj University, Yasouj, Iran
الکلمات المفتاحية: Optimal placement, Loss reduction, Capability, FACTS devices, Harmony search (HS) algorithm,
ملخص المقالة :
Given the high costs of investment for transmission network development and the key role of transmission networks in restructured space, using FACTS devices is crucial. In this paper, the optimal Placement of FACTS in transmission networks is investigated. In the proposed method, the objective function is defined for loss reduction a. Average models available in references are used for modeling FACTS devices. The multi-objective harmony search algorithm is used for problem-solving. This algorithm has good speed in the convergence of non-linear problems. In the numerical studies section, the problem is solved in two different scenarios with the presence of different types of FACTS devices. Results of numerical studies indicate that FACTS devices can have a considerable impact on loss reduction.
Abdelaziz L., & and Mohamed Boudour., (2009), “Optimal Location of SVC for Voltage Security Enhancement using MOPSO”. Journal of electrical systems, Special Issue No.1, 73-78.
Afkousi-Paqaleh, M., Rashidinejad, M., & Pourakbari-Kasmaei, M. (2010). An implementation of harmony search algorithm to unit commitment problem. Electrical Engineering, 92, 215-225.
Avinash. R, Savyasachi. G. K, Gowtham. N, Rakshith. P, (2015) “Optimal Location of STATCOMS using FVSI” International Advanced Research Journal in Science, Engineering and Technology Vol. 2, Issue 6,
Azadani, E. N., Hosseinian, S. H., & Hasanpor, P. (2008). Optimal placement of multiple STATCOM for voltage stability margin enhancement using particle swarm optimization. Electrical Engineering, 90, 503-510.
Baghaee, B. Vahidi, S. Jazebi, G. B. Gharehpetian and A. Kashefi, (2008). Power System Security Improvement by Using Differential Evolution Algorithm Based FACTS Allocation. Joint International Conference on Power System Technology and IEEE Power India Conference, New Delhi, India, pp. 1-6.
Besharat, H., & Taher, S. A. (2008). Congestion management by determining optimal location of TCSC in deregulated power systems. International Journal of Electrical Power & Energy Systems, 30(10), 563-568.
Bindeshwar Singh.; Sharma, N. K.; and Tiwari, A.N. (2010), “Prevention of Voltage Instability by Using FACTS Controllers in power systems”: a literature survey.International Journal of Engineering Science and Technology, 2(5), 980-992.
Canizares, C. A., Pozzi, M. Corsi S.& Uzunovic, E. (2003) “STATCOM modeling for voltage and angle stability studies,” Elect. Power and Energy Syst., vol. 25, pp. 431–441, 2003.
El Metwally M. M., El Emary A.A., El Bendary F. M., & Mosaad M.I., (2008). Optimal Allocation of FACTS Devices in Power System Using Genetic Algorithms., IEEE Trans.
Esmaili, H., Ramezani, Y., & Hemmatyar, A. M. A. (2012). ATC enhancement using SSSC, a case study of harmony search vs PSO. J. Basic Appl. Sci. Res, 2, 3416-3425.
Gaur, D., & Mathew, L. (2018). Optimal placement of FACTS devices using optimization techniques: A review. In IOP Conference series: materials science and engineering (Vol. 331, No. 1, p. 012023). IOP Publishing.
Ildarabadi, R, Nejad, M. B., & Sutikno, T. (2017). A new structure of dynamic voltage restorer based on asymmetrical γ-source inverters to compensate voltage disturbances in power distribution networks. International Journal of Power Electronics and Drive Systems, 8(1), 344.
Irshad, H. Ullah, I., Ali, W., Muhammad, G., & Ali, Z. (2022). Exploiting lion optimization algorithm for sustainable energy management system in industrial applications. Sustainable Energy Technologies and Assessments 52: 102237.
Javadian, A., Zadehbagheri, M., Kiani, M. J., Nejatian, S., & Sutikno, T. (2021). Modeling of static var compensator-high voltage direct current to provide power and improve voltage profile. International Journal of Power Electronics and Drive Systems (IJPEDS), 12(3), 1659-1672.
Jordehi AR, Joorabian M. (2011). Optimal placement of Multi-type FACTS devices in power systems using evolution strategies. In: Power engineering and optimization conference (PEOCO), 2011 5th international: IEEE; 2011. p.352–7.
Kavitha, K., & Neela, R. (2016). Comparison of BBO, WIPSO & PSO techniques for the optimal placement of FACTS devices to enhance system security. Procedia Technology, 25, 824-837.
Kiani, M, et al. (2023), A new method for online evaluation of the effects of PV panels and comparison with MVDI in electrical power distribution networks. Renewable Energy Focus, 44, 106-123.
Kowsalaya, M. K., Ray K.& Kothari D. P. (2008). Voltage Stability Enhancement Through Optimal Location of Var Compensator", ICSET, 2008.
Lashkar Ara, A., Rahmani, A. H., Parham, E. & Behshad, M. (2012) “multi-objective dynamic optimal power flow through the ε-constraint method with non-smooth and non-convex fuel cost functions”, Energy Education Science and Technology Part A: Energy Science and Research 2012 Volume (issues) 29(2): 1003-1014.
Malakar, T.; Sinha, N.; Goswami, S. K.; and Saikia, L. C., (2010). “Optimal Location and Size Determination of FACTS Devices by using Multiobjective Optimal Power Flow”, TENCON, 474-478.
Movahedpour, M., Kiani, M. J., Zadehbagheri, M., & Mohammadi, S. (2022). Microgrids operation by considering demand response and supply programs in the presence of IGDT-based reverse risk. IEEE Access, 10, 48681-48700.
Naderi, E., Pourakbari-Kasmaei, M., & Abdi, H. (2019). An efficient particle swarm optimization algorithm to solve optimal power flow problem integrated with FACTS devices. Applied Soft Computing, 80, 243-262.
Nguimfack-Ndongmo JdD, Kenné G, Kuate-Fochie R, Cheukem A, Fotsin HB,Lamnabhi-Lagarrigue F. A.(2009) simplified nonlinear controller for transient stability enhancement of multimachine power systems using SSSC device. Int J Electr Power Energy Syst 2014; 54:650–7. Del Valle YE. Optimization of power system performance using facts devices, PhD dissertation, Georgia Institute of technology.
Phadke, A. R., Fozdar, M. Niazi, K. R. (2012) “A new multi-objective fuzzy-GA formulation for optimal placement and sizing of shunt FACTS controller”, Applied Energy 40, 46-53
Pishavaei, M., Ildarabadi, R., & Sutikno, T. (2017). The coordinated control of FACTS and HVDC using H-infinity robust method to stabilize the inter-regional oscillations in power systems. Int. J. Power Electron. Drive Syst, 8(3), 1274-1284.
Rahimzadeh, S., & Bina, M. T. (2011). Looking for optimal number and placement of FACTS devices to manage the transmission congestion. Energy conversion and management, 52(1), 437-446.
Rahmani, E., Mohammadi, S., Zadehbagheri, M., & Kiani, M. (2023). Probabilistic reliability management of energy storage systems in connected/islanding microgrids with renewable energy. Electric Power Systems Research, 214, 108891.
Rashed, G. I., Sun, Y., & Shaheen, H. I. (2012). Optimal location and parameter setting of TCSC for loss minimization based on differential evolution and genetic algorithm. Physics Procedia, 33, 1864-1878.
Ravi, K., & Rajaram, M. (2013). Optimal location of FACTS devices using improved particle swarm optimization. International Journal of Electrical Power & Energy Systems, 49, 333-338.
Shaheen, H. I.; Rashed, G. I.; & Cheng, S. J., (2008), “Optimal Location and Parameters Setting of UPFC based on GA and PSO for Enhancing Power System Security Under Single Contingencies”. IEEE Proc., Powerand Energy society General Meeting Conversion and Delivery of Electrical Energy in the 21stCentury.
Sharma A, Chanana S, Parida S. (2005). Combined optimal located of FACTS controllers and loadability enhancement in competitive electricity markets using MILP. In: IEEE power engineering society general meeting (IEEE ESGM 2005), San Francisco, California, USA; 12–16 June 2005. p. 670–7.
Shintemirov, A., W. J. Tang, W. J., Tang, W. H. & Wu Q.H. (2010). Improved modelling of power transformer winding using bacterial swarming algorithm and frequency response analysis, Electric Power Systems Research, vol. 80, pp. 1111–1120.
Vijyakumar K. & Kumudinidevi R.P., (2008) “A Hybrid Genetic Algorithm for Optimal Power Flow Incorporating FACTS Devices”, Asian Journal of Scientific Research, pp. 403-411.
Zadehbagheri, M., Ildarabadi, R., & majid Javadian, A. (2023). Optimal Power Flow in the Presence of HVDC Lines Along with Optimal Placement of FACTS in order to Power System Stability Improvement in Different Conditions: Technical and Economic Approach. IEEE Access.
Zadehbagheri, M, Payedar, A. (2015). “The feasibility study of using space vector modulation inverters in two-level of integrated photovoltaic system”. TELKOMNIKA Indonesian Journal of Electrical Engineering, 14(2), 205-214.
Zadehbagheri, M., Ildarabadi, R., & Sutikno, T. (2023). A unified power flow controller-based robust damping controller considering time delay in electrical power systems. Indonesian Journal of Electrical Engineering and Computer Science, 31(3), 1295-1310.